Dent Instruments | High accuracy CT 15A
15 A High Accuracy CT
Courant nominal : 15A
gamme : de 0.15 à 20A
sortie : 333 mV @ 15A AC
diamètre d'enserrage : 10mm
précision : +/- 0.5%
KEY SPECIFICATIONS
Window Size ................. 0.4” (10 mm)
Current Range* .................0.15 ‐ 20 AC
Output ..............................333 mV @ 5 A AC
Ratio Error** .....................0.5% from 0.5% to 140% of rated current
Phase shift ......................0.5% at rated current
* Depending on meter compatibility. See ELITEpro™ and PowerScout™ specifications for details.
** For maximum performance. keep CT contact surfaces wiped clean and free of debris
ELECTRICAL
Output ........................................333 mV rated current
Wire Polarity ...............................White = Hi. positive (+) Black = Low. negative (-)
Frequency Range .......................10 Hz to 10 kHz
MECHANICAL
Weight ..................................... 136g
Dimensions .............................. 64*25*51mm
SAFETY
Working Voltage 600 VAC
Dielectric Strength 5000 VAC
105-Max measure current (A) | 20A |
428-Jaw opening | 10mm |
520-Sensor type | Classic, Hall effect |
118-Output type (V/C) | Voltage |
149-Probe accuracy (%) | 0.5% |
117-Current measurement type (AC/DC) | AC |
120-Safety Overvoltage | 5000VAC |
35-Dimension (HxWxD) (mm) | 64x51x25mm |
- Brochures
- Support