_AlertIE
-15%

Beha-Amprobe | 34XR-A TTD

TRMS Handheld digital multimeter; 4,000 counts; 1000V DC/750V AC,10A AC/DC

Beha-Amprobe
Reference : AMP34XR-A-TTD
Serie : 30XR-A
Purchase Order Reference : 34XR-A-TTD
Brand : Beha-Amprobe
****
Matériel de démonstration reconditionné. Sous réserve de disponibilité.
**** 

Mesures TRMS
Gamme de capacité étendue de 4 000 uF pour les tests de démarrage et de fonctionnement des moteurs
Rétro-éclairage
Rapport cyclique, fréquence, capacité
Température jusqu'à 1 000 °C avec thermocouple de type K fourni
Etui Magne-Grip™ avec sangle de suspension magnétique
Gel de l'affichage, valeurs Min/Max et graphique à barres
CAT III 600 V, CAT II 1000 V
TTCHT
Quantity
En Stock
Quick quote for this product
Quick quote for this product
Details
34XR-A
True RMS digital multimeter with temperature and backlightfor contractors and field service technicians.

For more features and specs on Capacitance.Temperature. Frequency. Duty Cylce. Diode Test. Overload Protection please click on the Detailed Specs link.


  • Autoranging; Display: 3-3/4 digit LCD. 3999 counts with 41-segment analog bar graph
  • Display Update Rate: 2/sec. nominal
  • Operating Temperature: 0 °C to 45 °C at < 70 % R.H
  • True RMS digital multimeter with temperature and backlight
  • Overrange indication
  • Auto power off to save battery life
  • Min/Max. Data Hold and Range Lock
  • Separate door for easy battery and fuse access
  • Magne-Grip™ Holster with magnetic hanging strap

 

Specifications
DC Voltage
Ranges400 mV. 4 V. 40 V. 400 V. 1000 V
Accuracy all ranges:± (0.5 % rdg + 1 dgt)
Resolution100 µV
AC Voltage (45 Hz to 2 kHz) True RMS
Ranges400 mV. 4 V. 40 V. 400 V. 750 V
Accuracy 400 mV range. 45 to 100 Hz:± (1.2 % rdg + 8 dgts)
Accuracy 750 V range: 45 to 1 kHz:± (2.0 % rdg + 8 dgts)
Accuracy All other ranges. 45 to 500 Hz:± (1.2 % rdg + 8 dgts)
Accuracy All other ranges. 500 to 2 kHz:± (2.0 % rdg + 8 dgts)
Resolution100 µV
AC coupledTrue RMS specified from 5 % to 100 % of range
DC Current
Ranges400 µA. 4 mA. 40 mA. 300 mA. 10 A
Accuracy 400 µA to 300 mA ranges:± (1.0 % rdg + 1 dgt)
Accuracy 10 A range:± (2.0 % rdg + 3 dgts)
Resolution0.1 µA
AC Current (45 Hz to 1 kHz) True RMS
Ranges400 µA. 4 mA. 40 mA. 300 mA. 10 A
Accuracy 400 µA to 300 mA ranges:± (1.5 % rdg + 8 dgts)
Accuracy 10 A range:± (2.5 % rdg + 10 dgts)
Resolution0.1 µA
Resistance
Ranges400 Ω. 4 kΩ. 40 kΩ. 400 kΩ. 4 MΩ. 40 MΩ.
Accuracy 400. 4 k. 40 k. 400 k. 4 MΩ ranges:± (1.0 % rdg + 4 dgts)
Accuracy 40 MΩ range:± (2.0 % rdg + 5 dgts)
Resolution100 mΩ
Capacitance
Ranges4 µF. 40 µF. 400 µF. 4000 µF
Accuracy 4 µF range:± (5.0 % rdg + 10 dgts)
Accuracy 40 µF. 400 uF ranges:± (5.0 % rdg + 5 dgts)
Accuracy 4000 µF range:± (5.0 % rdg + 15 dgts)
Resolution1 nF
Temperature
Ranges-20 °C to 1000 °C. -4 °F to 1832 °F
Accuracy -20 °C to 10 °C:± (2.0 % rdg + 4 °C )
Accuracy 10 °C to 200 °C:± (1.0 % rdg + 3 °C )
Accuracy 200 °C to 1000 °C:± (3.0 % rdg + 2 °C )
Accuracy -4 °F to 50 °F:± (2.0 % rdg + 8 °F)
Accuracy 50 °F to 400 °F:± (1.0 % rdg + 6 °F)
Accuracy 400 °F to 1832 °F:± (3.0 % rdg + 4 °F)
Resolution1 °C. 1 °F
Frequency
Ranges4 kHz. 40 kHz. 400 kHz. 4 MHz. 40MHz
Accuracy all ranges:± (0.1 % rdg + 3 dgts)
Resolution1 Hz
Duty Cycle
Ranges0 to 90 %
Accuracy 5 V logic:± (2.0 % rdg + 5 dgts)
Frequency Range40 Hz to 20 kHz
Continuity
Audible Indication< 35 Ω
Diode Test
Test Current1.2 mA (approximate)
Open Circuit Volts3.0 V dc typical
Overload Protection
AC/DC Voltage All ranges1000 V dc or 750 V ac rms
AC/DC Current µA/mA input:0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
AC/DC Current 10 A input:10 A /1000 V fast-blow ceramic 10 x 38 mm (10 A for 4 minutes maximum followed by a 12 minute cooling period)

General Specifications
Autoranging; Display
3-3/4 digit LCD. 3999 counts with 41-segment analog bar graph
Display Update Rate
2/sec. nominal
Power Battery
9 V NEDA 1604. JIS 006P. IEC 6F22
Battery Life
200 hrs typical (alkaline) frequent use of backlight will decrease battery life
Operating Temperature
0 °C to 45 °C at < 70 % R.H.
Storage Temperature
-20 °C to 60 °C. 0 to 80 % R.H. with battery removed from meter
Dimensions
7.75" x 3.55" x 2.4" (196 x 92 x 60mm)
Weight without holster. including battery)
(1 lb (400 gr)
Voltage AC
750 TRMS AC
Voltage DC
1000 V
mV AC
TRMS
Basic DC Accuracy
0.5%
DC Current. fused
10 A
AC Current. fused
10 A TRMS
Resistance
40MΩ
Capacitance
4000µF
Frequency
40 MHz
Temperature
1832°F/1000°C

Product Details
41-Standard Manufacturer Warranty 3 YEARS
27- Resolution in nb points 4,000 counts
33-additional measurements Resistance | Capacitance | Frequency | Temperature | Continuity test | Diode test | Min/Max | Duty cycle
424-TRMS Yes
435-Data logger on PC No
436-Functions Backlight | Bargraph | Fuse protection
449-Direct input for current probe No
462-Current AC (Alternative) | DC (Continuous)
463-Voltage AC (Alternative) | DC (Continuous)
23-Voltage resolution 100uV
34-Bandwidth 20kHz
45-PC interface na
24-Accuracy (%) 0.5%
37-Max. DC voltage 1000V DC
38-Max. AC voltage 750V AC
25-Autonomy 200 hour
39-Max. DC current 10A DC
40-Max. AC current 10A AC
119-Safety Level CAT I | CAT II | CAT III
120-Safety Overvoltage CAT II 1000V / CAT III 600V
36-Additional Characteristics -
132-Package includes Test leads,9 V battery (installed), Magne-Grip™ Holster withmagnetic hanging strap, Temperature adapter (TA-1),Type K thermocouple probe (TP255A), users manual
35-Dimension (HxWxD) (mm) 196x92x60 mm (7.7x3.5x2.3 inch)
13-Net Weight 426 g (1 lb)