_AlertIE

Fluke | 115

TRMS Handheld digital multimeter; 6,000 counts; 0.5% accuracy

Fluke
Reference : FLU115
Serie : 110
Purchase Order Reference : FLUKE-115 EUR (2583583)
Brand : Fluke
Multimètre pour tests de terrain. Pour les tests électriques et électroniques de terrain, les essais industriels, etc... * Mesures efficaces vraies TRMS * Précision de base de 0,5% * Résolution de 6000 points * AutoVolt: sélection automatique de tension AC/DC * Grand rétro éclairage blanc permettant de travailler dans les zones mal éclairées. * Résistance et continuité * Caractéristiques MIN/MAX/MOY permettant d'enregistrer les fluctuations du signal * Certifié CAT III 600 V
TTCHT
Quantity
En Stock
Quick quote for this product
Quick quote for this product
Details

Model 115

 

 

An everyday multimeter for technicians. the 115 is optimized for electrical and electronic testing in field service. industrial. and applications where more than basic functionality (such as measurement of ac/dc current) simplifies working.

Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III. Pollution Degree 2
Display
Digital:6.000 counts. updates 4 per second
Bar graph
33 segments. updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline. NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical. without backlight

Accuracy Specifications
DC millivolts
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.00 V / 0.1 V
Accuracy:± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0 % + 3 (dc. 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0 % + 3 (dc. 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.0 V / 0.1 V
Accuracy:1.0 % + 3 (dc. 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beeper on < 20 Ω. off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:600.0 Ω / 0.1 Ω
Range/Resolution:6.000 kΩ / 0.001 kΩ
Range/Resolution:60.00 kΩ / 0.01 kΩ
Range/Resolution:600.0 kΩ / 0.1 kΩ
Range/Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9 % + 1
Range/Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5 % + 2
Diode Test
Range/Resolution:2.00 V / 0.001 V
Accuracy:0.9% + 2
Capacitance
Range/Resolution:1000 nF / 1 nF
Range/Resolution:10.00 µF / 0.01 µF
Range/Resolution:100.0 µF / 0.1 µF
Range/Resolution:9999 µF / 1 µF
Range/Resolution:100 µF to 1000 µF
Accuracy:1.9% + 2
Range/Resolution:> 1000 µF
Accuracy:5% + 20%
Lo-Z Capacitance
Range:1 nF to 500 µF
Accuracy:10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution:6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy:1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/Resolution:6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy:1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution:99.99 Hz / 0.01 Hz
Range/Resolution:999.9 Hz / 0.01 Hz
Range/Resolution:9.999 kHz / 0.001 kHz
Range/Resolution:50 kHz / 0.01 kHz
Accuracy:0.1% + 2

Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled. 5 Hz to 50 kHz for ac voltage.

2) Frequency is ac coupled. 5Hz to 30 kHz for ac voltage

Mechanical & General Specifications
Size
Height:16.7 cm (6.57")
Length:8.4 cm (3.31")
Width:4.62 cm (1.82")
Weight
392 g (0.866 lbs)
Warranty
3 years

 

Product Details
41-Standard Manufacturer Warranty 3 YEARS
27- Resolution in nb points 6,000 counts
33-additional measurements Resistance | Capacitance | Frequency | Continuity test | Diode test | Min/Max
424-TRMS Yes
435-Data logger on PC No
436-Functions Large display | Backlight | Bargraph | Fuse protection
449-Direct input for current probe No
462-Current AC (Alternative) | DC (Continuous)
463-Voltage AC (Alternative) | DC (Continuous)
23-Voltage resolution 0.1 mV
34-Bandwidth 50 kHz
45-PC interface na
24-Accuracy (%) 0.5%
37-Max. DC voltage 600V DC
38-Max. AC voltage 600V AC
25-Autonomy 400 hours
39-Max. DC current 10A DC
40-Max. AC current 10A AC
119-Safety Level CAT I | CAT II | CAT III
120-Safety Overvoltage CAT III 600V
36-Additional Characteristics -
132-Package includes Holster, installed 9 V battery, TL 75 Test leads, user manual
35-Dimension (HxWxD) (mm) 167x84x46 mm
13-Net Weight 550 g