_AlertIE

Kyoritsu KEW 2009R

Pince de courant 2000A AC/DC, TRMS, CATIV, machoire 55mm - avec sortie analogique

Kyoritsu
Reference : KYOK2009R
Purchase Order Reference : K2009R
Brand : Kyoritsu
Pince multimètre.
Mesures TRMS jusqu'à 2000A AC/DC, 750/1000 AC/DC.
Sécurité CAT IV 600V.
Machoires ouvrables jusqu'à 55mm.
Sortie analogique en tension.
VAT incl VAT excl
Quantity
Expédié sous 1 semaine
Quick quote for this product
Quick quote for this product
Details

KEW 2009R

 

2000A TRMS AC/DC Digital Clamp Meter with analog output

 

• CAT IV Clamp Meter can measure the Voltage and Current in both very low and high power circuits.
• Accurate True-RMS reading of AC current or voltage with distorted waveform.
• Can measure AC and DC currents up to 2000A.
• Output terminal for connection to recorders.

 

AC A400.0/2000A
±1.3%rdg±3dgt (0 - 400.0A. 150 - 1700A) (45 - 66Hz)
±2.0%rdg±5dgt (0 - 400.0A. 150 - 1700A) (20Hz - 1kHz)
±2.3%rdg±3dgt (1701 - 2000A) (45 - 66Hz)
DC A400.0/2000A±1.3%rdg±2dgt
AC V40.00/400.0/750V
±1.0%rdg±3dgt (45 - 66Hz)
±1.5%rdg±5dgt (20Hz - 1kHz)
DC V40.00/400.0/1000V±1.0%rdg±2dgt
Ω400.0/4000Ω ±1.5%rdg±2dgt
(Electronic protection (no fuse) up to 600V)
Continuity buzzerBuzzer sounds below 20Ω
Hz10.0 - 4000Hz±1.5%rdg±5dgt
(Input sensitivityCurrent: more than 40AVoltage: more than 10V)
Conductor sizeØ55mm max.
OutputRecorder :
DC400mV against AC/DC400.0A
DC200mV against AC/DC2000A
Applicable standardsIEC 61010-1 CAT IV 600V. CAT III 1000V Pollution degree 2
IEC 61010-031. IEC 61010-2-032. IEC 61326-1. IEC 61326-2-1
Power sourceR6 (1.5V) × 2
Dimensions250(L) × 105(W) × 49(D)mm
WeightApprox. 540g (including batteries)
Included Accessories7107A (Test leads). 8201 (Output plug). 9094 (Carrying case)
R6 (AA) (1.5V) × 2. Instruction Manual
Product Details
41-Standard Manufacturer Warranty 3 YEARS
27- Resolution in nb points nc
33-additional measurements Resistance | Frequency | Continuity test
424-TRMS Yes
428-Jaw opening Diam 55mm max
462-Current AC (Alternative) | DC (Continuous)
463-Voltage AC (Alternative) | DC (Continuous)
750-IR imaging inside No
34-Bandwidth DC; 20Hz-1kHz
37-Max. DC voltage 1000V DC
38-Max. AC voltage 750V AC
25-Autonomy nc
39-Max. DC current 2000A DC
40-Max. AC current 2000A AC
119-Safety Level CAT III | CAT IV
En Stock No
120-Safety Overvoltage CAT IV 600V / CAT III 1000V
36-Additional Characteristics Analog voltage output
132-Package includes K2009R, 2 AA 1.5V batteries, test leads with touch points, analog output plug, handstrap, carrying softcase, user manual
35-Dimension (HxWxD) (mm) 250x105x49 mm
13-Net Weight 540 g